Metal tile roofs – tile edge lifting
Listed under: metal, Roof, cladding, fixings and hardware, fixings, roof cladding, metal tiles
Cause
Inadequate fixing along the front edge of tiles
Repair
- if the tiles were installed in recent years, call back the installer to make the repairs
- check the manufacturer’s recommendation for fixing the tiles
- where this is not known, install extra 50 x 2.8 mm hot-dipped galvanised flat-head annular-grooved nails to the top front edges of lifting tiles. Use neoprene washers containing no more than 15% by weight carbon black content. (You can find fixing details in section 8.3.7 and Figure 36 of Building Code Acceptable Solution E2/AS1.)
- always tell someone else when you plan to work on a roof and take the appropriate safety precautions. You can find details here