Metal tile roofs – water does not drain into gutter

Cause

Tiles stop short of the gutter

Repair

  • if the tiles were installed in recent years, call back the installer to make the repairs
  • obtain the installation requirements from the tile manufacturer to see what overhang over the gutter is recommended or required
  • you can find the installation requirements of pressed metal tiles in section 8.3 of Building Code Acceptable Solution E2/AS1.) Figure 36 shows that the metal tile must overhang the fascia by a minimum 40 mm at the closest point of the tile
  • one option may be to lift the bottom tile and insert a purpose-made eaves flashing under the roofing to overhang the back upstand of the gutter. This should only be done if you have the experience, knowledge and tools to do the job effectively. The result may not be attractive (but may not be very visible from the ground)
  • for most people the best option will be to engage a registered tradesperson to undertake the repairs
  • always tell someone else when you plan to work on a roof and take the appropriate safety precautions. You can find details here