There is no gap between the bottom of the cladding and a window/door head flashing (gap should be 5 mm)

  • It was not installed correctly when constructed – the gap has been required under E2/AS1 for building work since 1992 to allow draining and drying from behind the cladding

    How to repair

Gap between bottom of cladding and head flashing sealed

  • It was not installed correctly when constructed – the gap has been required under E2/AS1 for building work since 1992 to allow draining and drying from behind the cladding

    How to repair

Gap between bottom aluminium window flange and cladding sealed

  • It was not installed correctly when constructed – the gap has been required under E2/AS1 for building work since 1992 to allow draining and drying around the window

    How to repair

Aluminium window flange is fitted tightly to direct-fixed cladding

  • It was not installed correctly when constructed – E2/AS1 for building work since 1992 has required that the window is installed with a 5 mm gap between the back of the flange and the cladding – the gap can be sealed down each side (jamb) of the window and left open across the sill

    How to repair

Leaking through stucco

EIFS – leaking through cladding

House is draughty

Polystyrene block – cracks in the cladding systems

Earth construction – leaking through cladding

Straw bale construction – leaking through cladding

Windows – water entry around windows